Writing

36 articles, newest first. One more is published each week.

  1. DC:AC Ratio: Choosing an Inverter Size From Your Own Curve Turns inverter selection into an optimisation problem using your modelled DC output distribution, showing why UK conditions justify oversizing the array relative to the inverter and where that stops paying. 7 min
  2. Winter Is the Honest Season: Modelling November to February Properly Argues that models validated on summer data hide their errors, and shows how to check a forecast against the low-sun months where diffuse fraction, shading and low irradiance thresholds dominate. 8 min
  3. Cleaning Messy Export Files Before You Analyse Them Catalogues the specific corruptions in UK energy exports — DST duplicate hours, missing half-hours, cumulative-vs-interval confusion, meter exchanges, timezone drift — and gives validation checks that catch each before they poison your model. 7 min
  4. Simulating a Year of Battery Dispatch on Half-Hourly Data Builds a state-of-charge simulation row by row with charge/discharge limits and losses, then uses it to test battery sizes — the step that turns 'a battery sounds good' into a defensible capacity decision. 7 min
  5. Inverter Clipping: How to Tell If It's Actually Costing You Anything Shows how to detect clipping from the flat-topped shape of your generation curve, quantify the lost kWh over a year, and conclude — usually — that in the UK the clipping you can see is cheaper than the inverter that would prevent it. 6 min
  6. Discount Rates, Energy Inflation and the Honest Payback Number Replaces simple payback with NPV and IRR, shows how sensitive the result is to assumed energy price inflation, and argues for quoting a range with stated assumptions instead of a single reassuring year count. 6 min
  7. Heat Pump, EV or Neither: Sizing for the Consumption You'll Have in 2030 Builds forward load scenarios by grafting modelled heat pump and EV profiles onto your existing data, arguing that sizing to today's consumption locks in an undersized array just before your demand doubles. 7 min
  8. Degradation, Soiling and Tilt: Building an Honest Loss Stack Assembles every derate factor from module to meter with UK-specific values and evidence for each, then shows how to apply them multiplicatively rather than the lazy flat 'minus 20%' most models use. 8 min
  9. Local LLMs vs Cloud for Your Household Energy Data Assesses the real trade-off for energy analysis specifically — half-hourly data is an occupancy record — comparing local model capability on tabular reasoning against cloud quality, with a hybrid split that keeps raw data at home. 6 min
  10. Arbitrage Maths: When Charging From the Grid Beats Storing Your Own Solar Derives the break-even condition where cheap import plus round-trip losses undercuts the opportunity cost of stored solar, and shows the counter-intuitive result that on some tariffs you should export in summer and import at night. 7 min
  11. Clear-Sky Ceilings: Using Theoretical Maxima to Spot Underperformance Shows how to compute a clear-sky upper bound for any given day and use the gap between it and your actual output as a fault signal that works even without irradiance sensors on site. 7 min
  12. Sanity-Checking an Installer's Yield Claim in Ten Minutes Provides a fast triage that catches inflated yield figures — specific yield per kWp, implied performance ratio, MCS versus marketing estimate — and shows what an optimistic-but-defensible number looks like versus an indefensible one. 8 min
  13. Roof Space Constraints: From Panel Dimensions to a Real Layout Converts your measured roof into an actual panel count using real module dimensions, edge setbacks, obstructions and portrait/landscape trade-offs — the step that turns a theoretical kWp target into a buildable array. 9 min
  14. East-West vs South: Modelling Orientation Against Your Own Load Curve Demonstrates that the orientation producing the most kWh is often not the one producing the most value, using morning-and-evening-heavy load data where a split east-west array beats a south-facing one on self-consumption. 7 min
  15. Round-Trip Efficiency and Why Your Battery Loses 12% You Didn't Budget For Traces every loss between surplus generation and delivered household power — inverter, conversion, standby draw, thermal — and shows how ignoring them overstates battery savings by roughly a sixth. 8 min
  16. Detecting a Single Failed String From Your Generation Curve Teaches curve-shape diagnosis: what a dead string, a failed optimiser, a tripped MPPT and new shading each look like in daily generation data, so you can name the fault before you call anyone. 10 min
  17. Export Payments Modelled Properly: SEG Rates vs Real Behaviour Shows why headline SEG p/kWh rates mislead — export timing, tariff bundling, switching penalties — and builds an export revenue model driven by your own half-hourly surplus rather than an annual average. 8 min
  18. Building a Repeatable Data Pipeline from the Octopus and n3rgy APIs A concrete, scheduled pipeline — fetch, validate, append, archive — that turns one-off CSV downloads into a growing dataset, with the authentication and pagination gotchas that break naive scripts. 9 min
  19. Getting Free Weather and Irradiance APIs to Agree With Each Other Compares Open-Meteo, CAMS, Met Office and PVGIS TMY data for the same UK location, quantifies the spread, and recommends a blending approach so your forecast isn't hostage to one provider's bias. 7 min
  20. How Many Solar Panels Do You Actually Need? Three Methods Compared Compares rule-of-thumb sizing, roof-fill sizing and consumption-matched sizing on one real dataset, showing where each lands and why the consumption-matched answer should be your starting point and the roof-fill answer your ceiling. 8 min
  21. Agile, Go, Flux or Cosy: Matching a Tariff to Your Load Shape Runs the same household's real half-hourly data against each tariff's price structure to show that tariff choice is a data question with a calculable answer, not a matter of reputation or forum consensus. 6 min
  22. The First Month of Monitoring: Building Your Expected-vs-Actual Baseline A commissioning protocol for analysts: what to log in the first 30 days, how to compute a performance ratio, and how to lock down a reference baseline while the system is provably healthy. 8 min
  23. Shading Is Not Binary: Modelling Partial Shade Hour by Hour Shows how to build a horizon profile and sun-path overlay for your own roof, then translate it into hourly shading factors — replacing the installer's vague 'a bit of shading in the morning' with numbers. 9 min
  24. Cheap, Mid or Overpriced: Benchmarking £/kWp Across UK Quotes Builds a normalisation method that makes wildly different quotes comparable on a £/kWp and £/kWh-of-storage basis, with current UK bands and the legitimate reasons a quote can sit above them. 9 min
  25. Self-Consumption Rate: The Metric That Decides Your Payback Argues self-consumption rate, not system size or yield, is the lever with the largest effect on returns, and shows how to calculate yours from half-hourly data for several candidate array sizes. 7 min
  26. Writing Prompts That Don't Hallucinate Your Numbers Establishes prompt patterns for numerical work — supply the data, forbid estimation, demand shown arithmetic, require a stated method — and demonstrates the failure modes each pattern prevents with real solar examples. 10 min
  27. PVGIS in 20 Minutes: Getting a Trustworthy Baseline Yield A guided run through PVGIS for a UK roof, explaining every input that actually changes the answer and how to export hourly output for use in your own model rather than just reading the headline annual figure. 7 min
  28. Annual kWh Is a Trap: Why Your Load Shape Matters More Than Your Total Takes two households with identical annual consumption and shows their optimal solar sizing differs by 40% purely because of when they use power — the argument for abandoning annual-total sizing entirely. 7 min
  29. Battery Basics for Analysts: Usable vs Nameplate Capacity Unpicks nameplate kWh, depth of discharge, reserve settings and continuous power limits, showing that the number on the datasheet is rarely the number your model should use — and how to find the real one. 7 min
  30. What Your Smart Meter Dashboard Isn't Telling You Explains why in-home displays and app dashboards net off, round, aggregate and lag your data, and shows how to establish what your monitoring layer can and cannot detect before you rely on it to spot a fault. 7 min
  31. Reading a Solar Quote Line by Line Decomposes a real UK quote into panels, inverter, battery, scaffolding, DNO work, labour and margin, and shows which lines are genuinely fixed costs and which are the negotiable padding that varies threefold between installers. 7 min
  32. Your First Solar Model in a Spreadsheet: A 90-Minute Build Builds a deliberately minimal but correct model from scratch — 8,760 rows, generation, load, self-consumption, export — and argues this crude version is the artefact everything else in the year refines, so build it before touching any sophisticated tool. 7 min
  33. How to Measure Your Roof Without Getting on a Ladder A practical method for deriving pitch, azimuth and true usable area from free sources — Google Earth, LiDAR tiles, phone inclinometer, planning drawings — with an honest accuracy budget for each, so your forecast starts from real geometry rather than a guess. 10 min
  34. kW vs kWh: The Unit Confusion That Quietly Ruins Solar Spreadsheets Diagnoses the single most common modelling error — mixing power and energy in the same column — and gives a unit-discipline convention (plus prompts that force an AI to declare units) so your spreadsheet fails loudly instead of silently being wrong by a factor of two. 8 min
  35. The Five Numbers You Need Before You Model Solar At All Establishes the minimum viable dataset — annual kWh, daytime share, peak demand, usable roof area and roof azimuth/pitch — and shows that a model built on these five beats a slick online calculator that asks for your postcode and nothing else. 8 min
  36. Where to Get Your Own Half-Hourly Electricity Data (And Why It Changes Everything) Walks through every route to your own granular consumption data — supplier portal exports, the n3rgy DCC feed, Octopus API, IHD logging, CT clamps — and argues that until you have half-hourly data, every solar decision you make is guesswork dressed up as a calculation. 7 min